How Much Power Does a CCTV Camera Use? Read It, Don’t Guess
Every off grid sizing decision starts with one number, and that number is almost never printed on the box. A camera’s real draw changes with infrared, with pan and tilt, with the heater nobody mentioned, and with whether the model has a fan. This guide shows where to find the honest figure, how to measure it if the label is vague, and how to turn watts into the daily watt-hours that actually size a battery.
Q: How much power does a CCTV camera use?
A: Most fixed security cameras sit somewhere between 4 and 12 W of continuous draw, and a pan-and-tilt model with infrared running can reach 15 to 25 W. The honest figure for your camera is on its power supply or in its datasheet, expressed as volts times amps, and the only way to know the night-time number for certain is to measure it once with a DC meter. Multiply the watts you settle on by 24 to get daily watt-hours, and that figure, not the wattage alone, is what decides how much battery your site needs. Whether one camera closes that account at all is the three checks a camera has to pass, run in order before a model is picked.
Start With the Label, Then Distrust It Slightly
Two places carry the number. The first is the camera’s own datasheet, which usually quotes a maximum draw in watts. The second, and the more useful one for older equipment, is the power supply that came with it: read the output line, not the input line. An adapter marked 12 V DC 2 A has a 24 W ceiling, and that ceiling is the most the camera is allowed to pull, not what it pulls on average. An allowance read as a draw can even imitate a fault: when the battery stops filling, a camera that is not charging usually has a site cause before a hardware one.
That gap between ceiling and average is the whole reason sizing by nameplate goes wrong. A camera rated at 24 W might draw 6 W in daylight with infrared off, 9 W after dark with it on, and 18 W on the one cold night the internal heater kicks in. Size for 6 W and the site is dark by the second night. Size for the 24 W ceiling and you buy battery you never use. The working number is the realistic continuous draw at the worst moment of a normal night, which is why the label is the starting point rather than the answer. Holding that draw where it started over a few years is a lighter job than it sounds, and the seasonal check list is the whole of it.
One more label detail that catches buyers: a camera sold with a 12 V DC adapter and a camera sold with PoE are different loads even when the model name is nearly the same. The DC version runs directly from a 12 V output. The PoE version needs a PoE injector or switch, and that injector becomes part of the load you have to count.
Five Loads That Hide Behind One Wattage
Planning figures for the shapes of load we see on camera sites. These are reference ranges, not published specs for your equipment, so your meter or your datasheet replaces them. The current you measure there also sets the cable length that still works, worked in sizing a 12 V run.
| Load at a camera point | Typical continuous draw | What moves the number |
|---|---|---|
| Fixed bullet or turret camera | ≈4–8 W | Sensor size, compression, whether infrared is on for most of the night |
| Dome or PTZ with infrared | ≈15–25 W | Pan and tilt bursts on top of the baseline, longer infrared runs in winter |
| Heater or blower option | ≈10–20 W extra | Cold-climate housings that switch on by thermostat, and only in cold weather |
| 4G router or radio on the same system | ≈2–6 W | Idle versus transmitting, signal strength, whether the radio sleeps |
| NVR or local recording box | ≈5–15 W | Number of channels and whether a hard drive spins continuously |
Ranges describe equipment shapes, not a promise about any specific model. Whatever the label says replaces every number in this table.
If the Label Is Vague, Measure Once
Ten minutes with a DC clamp meter or an inline power meter settles the question permanently for a given camera model, and the reading is worth more than any datasheet. Measure with the camera doing its real job: infrared on, recording to whatever it records to, and network connected. Measure twice if the model has a heater, once at room temperature and once with the thermostat likely to have closed, because those two readings can differ by a factor of two.
Two habits make the reading usable. First, note the voltage at the same time as the current, because watts are volts times amps and a sagging supply changes both. Second, write both numbers on a label inside the enclosure or in the site file. The next person to size a point on that route should not have to repeat the measurement, and the same camera model will produce the same number on every copy of that site.
If measuring is impossible before purchase, ask the supplier for the input rating and treat the highest figure you are given as the planning number, then confirm it on the first unit. What you must not do is size the system on an average that assumes infrared is never used, because on a security camera infrared is used every single night.
From Watts to Watt-Hours: The Step Everyone Skips
How much power does a CCTV camera use, then, once the label and the meter have both been consulted? The answer only becomes useful when it is turned into watt-hours. A wattage on its own sizes nothing. A 10 W camera runs for 24 hours and asks for 240 Wh a day; a 20 W camera asks for 480 Wh. Both of those assume the camera works the whole day, and the duty cycle behind a 24/7 recording requirement is what decides whether it does. Those daily watt-hours are compared against usable battery energy. For these systems the figure is quoted at 12 V nominal, with the reserve the system keeps in hand and the conversion loss already taken off, which gives roughly 326 Wh on a 40 Ah battery, 490 Wh on a 60 Ah, and 979 Wh on a 120 Ah.
A worked example makes the comparison concrete. Take a fixed camera at 8 W and a router at 4 W, so 12 W continuous and 288 Wh a day. The router half of that figure is the one most lists leave under-counted, and the router load at a camera point covers it device by device. On the 60 Ah battery that is about 1.7 days of reserve, comfortable for a normal night and thin across two grey days. The 120 Ah battery gives about 3.4 days on the same load, which is the difference between a site that recovers from bad weather and one that needs a visit. Add a heater-equipped PTZ at 20 W and the daily figure climbs past 700 Wh, which pushes the same site onto the largest battery in the range. The panel and battery sizing method behind these numbers is written out step by step if you want to run your own figures through it. If the figures say the reserve reaches zero, the flat-battery walkthrough describes what that day looks like.
Then check the panel side. Recharge has to cover the daily consumption on a short day in the worst month, and that is a different calculation from the battery reserve. The battery decides how long a point survives; the panel decides whether it recovers. How farms size each camera point, where every point is its own site, is set out in this walkthrough. How a system behaves across a stretch of cloudy and cold weather is covered with numbers in that guide.
Four Ways This Number Gets Fudged
Counting daytime only. The camera runs at night, and infrared is on for most of it. A draw measured at noon on a sunny day is the low point of the day, not the average.
Ignoring the accessories. The router, the radio, the NVR and the PoE injector are all on the same output. A 6 W camera with a 5 W router is an 11 W site, and the second number doubles the first one’s importance. Add devices until the list is whole and the count question answers itself; the camera-count arithmetic is that sum worked twice, on watts and on watt-hours.
Treating the adapter rating as consumption. A 12 V 2 A adapter is a 24 W allowance, and most cameras never approach it. Sizing on allowances buys battery nobody needed and hides the real question, which is the measured night-time draw.
Assuming an inverter is needed. Cameras, routers and most NVRs run on low-voltage DC, which is what an off grid camera system outputs, so converting to mains-style AC only adds losses. Whether an inverter is needed for a solar camera system is one of the questions we answer most often, and the short version is that it usually is not.
Match the Battery to the Daily Watt-Hours
Same DC 12V output and the same 5 A ceiling across the range, so every model accepts the same category of load. What changes is how many watt-hours a night and a grey stretch can draw on.
| Model | Panel / battery | Usable energy | Daily budget it suits |
|---|---|---|---|
| 80w solar power system for camera | 80 W / 40 Ah | ≈326 Wh | ≈150–250 Wh a day, one light camera, carried in by hand |
| 120w solar power system for camera | 120 W / 60 Ah | ≈490 Wh | ≈250–380 Wh a day, camera plus router on a wall or post |
| YO-P12060-T | 120 W / 60 Ah | ≈490 Wh | The same budget where the only mount is a pole in open ground |
| 240w solar power system for camera | 240 W / 120 Ah | ≈979 Wh | ≈400–600 Wh a day, heaters and PTZ, or long grey stretches |
Daily budgets are reference bands, not a camera count. Every model shares the same 60 W (5 A at DC 12V) continuous ceiling, and the ceiling applies to the total on the output. What that ceiling means at a single camera point is worked through in solar power for a 12V security camera.
What the Wiring Looks Like
A single-camera run needs one cable: the DC5521 plug from the system output to the camera. The panel, controller and battery side is pre-wired at the factory, so there is no wiring diagram to follow on site and no mains work anywhere in the installation. Two cameras change one thing — a splitter at the output, sized against the same 5 A ceiling as everything else on the output.
That is the whole wiring task. What deserves the attention instead is upstream of it: the daily watt-hours the camera burns, which is what the earlier sections work through.
Quick Answers
Is 60 W enough for several cameras?
Does infrared change the draw?
What about the router and the recording box?
Do I need to measure every camera on a site?
Get your load checked
Send the camera and router models or their input ratings. You get daily watt-hours, the model that fits and the reserve it leaves, typically within 24 hours.
Send My NumbersSee the four sizes
Panel, battery, usable energy and brackets side by side, quoted FOB China.
Compare ModelsMinimum order 2 pcs · FOB China · Payment is 100% in advance, by T/T bank transfer · Standard models · Typical lead time ~15 days
80W vs 120W vs 240W Compared
What each size actually carries, and the differences the spec table does not show.
Cloudy Days and Cold Nights
How the daily watt-hours you just calculated behave across a grey week and a cold snap.
Remote Site Power, End to End
Pipelines, mines, highways and coastlines: what a typical point draws on each kind of route.